GENERAL
As part of a pulsed energy project, I needed to test a rather large power supply to achieve the desired results (48V @100A). For those that are looking, that’s 5Kw. This article discusses the design & implementation of a hybrid static/transient load testing instrument. This allows static load testing with superimposed transient capability in a single instrument.
Continue reading “High Voltage 100A Active Load with Transient Capability (Part One)”